Platform · Program 07-B

A single closed loop, from substrate to signed batch.

Reactor, control stack, and record — one system. Strain-agnostic hardware, model-driven set-points, a reproducible artifact at the end of every run.

01 · Reactor platform

Closed-loop fermentation, 2 — 200 L.

Modular vessel, modular instrumentation. pH, DO, temperature, feed, stir — every channel sensed, every channel actuated.

Volume2 — 200 L
Channels14
Vessel316L · Autoclave-safe
02 · Control stack

Model-driven set-points. Drift correction in seconds.

Designed for a 200 ms loop. Process models will hold set-points to tolerances a human cannot. No gain-tuning per batch — the stack learns from every run.

Loop200 ms
ModelMPC + residual NN
FallbackPID · hot-swap
03 · Batch record

Signed, reproducible, audit-ready.

Every sensor read, every correction, every harvest will be hashed and signed. Replay any run. Diff two batches. Export for audit — built for the regulated environments biology requires.

FormatGxP-aligned
Standard21 CFR Part 11
RetentionImmutable, chained
Development approach

Months of learning, compressed into days.

At the core of our platform is a micro-reactor testbed — a high-throughput experimental system that allows us to run hundreds of parallel biological experiments under controlled conditions.

  • Rapidly explore process conditions
  • Map how parameters affect yield and stability
  • Identify failure patterns early
  • Build reproducible process baselines

Instead of optimizing a process over months, we compress that learning into days.

The run

Four stages. No operator in the middle.

Stage 01t=0

Init

Recipe loaded. Vessel sealed. Sensors calibrated against traceable standards.

Stage 02t=0 — 72h

Run

Closed loop designed to hold set-points. Feed profile executes on schedule. Drift caught and corrected before it accumulates.

Stage 03Harvest

Harvest

Window detected by model, not clock. Product transferred. Vessel readied for CIP.

Stage 04Export

Record

Batch artifact signed, chained to prior runs, exported. Reproducible, diffable, auditable.

Program specs · 07-B

The numbers we are building toward.

Working volume
2 — 200 L
Per unit. Modular, rack-mountable.
Control loop
200 ms
Set-point → actuation. Deterministic.
Set-point tolerance
±0.02 pH · ±0.05°C
Typical, steady-state.
Operator hours
0.00 / run
Post-init. 72-hour campaign, unattended.
Record format
GxP-aligned, CFR Part 11
Signed, immutable, chained.
Strain
Agnostic
Bacterial, yeast, mammalian in development.
Status
In development
Alpha partners onboarding, Q1 2027.
Partners

We are selectively briefing alpha partners.

Request a briefing